Guide Setup Siemens STEP7 V5.6 / STEP7 Professional 2017Download Link: https://plc247.com/download-step7-v5-6-pro-for-s7-300-s7-400-siemens-googledrive/Pleas. SIMATIC S7, STEP 7 V5.6 SP2, Floating License for 1 user, E-SW, SW and docu. On DVD, license key on USB flash drive, Class A, 5 languages (de,en,fr,es,it), executable in Windows Server 2008 R2 SP2, Windows Server 2012 R2, Windows Server 2016, Windows Server 2019, Windows 7 SP2, Windows 10 Professional, Windows 10 Enterprise Reference HW: S7-300. 修改的STEP7 Professional 2017 SR2中文版,里面包含最新的STEP7 V5.6 SP2中文吧,安装之后仿真也是中文版的下载地址:链接:https://pan.
ScreenShots:
Software Description:
Siemens SIMATIC STEP 7 software is theprofessional tool for the SIMATIC S7, SIMATIC C7 and SIMATIC WinACautomation systems. It enables the user to use the performancecapability of these systems easily and conveniently.
SIMATIC STEP 7 contains convenient functions for all phases of anautomation project:
– Configuring and parameterizing the hardware
– Specifying the communication
– Programming
– Test, start-up and service
– Documentation, archiving
– Operating/diagnostics functions
SIMATIC STEP 7 program tools:
1. SIMATIC-Manager:
The SIMATIC Manager manages all data belonging to an automationproject, regardless of the target system (SIMATIC S7, SIMATIC C7 orSIMATIC WinAC) on which they are implemented.
It provides a common entry point for all SIMATIC S7, C7 or WinACtools. The SIMATIC software tools that are necessary for processingthe selected data are automatically started by SIMATIC Manager.
2. Symbol-Editor:
With the tool Symbol Editor all global variables (in contrast tothe local formal parameters that are declared when the blocks areprogrammed) are managed. The following functions are available:
– Definition of symbolic designations and comments for the processsignals (inputs/outputs), flags and blocks
– Sorting functions
– Data exchange with other Windows programs
The symbol charts that are generated when this tool is used areavailable to all software products. Changes to a symbol parameterare therefore automatically recognized by all tools.
3. Hardware configuration:
The tool Hardware Configuration is used for configuring andparameterizing the hardware used for an automation project. Thefollowing functions are available:
– Configuration of the automation system Racks are selectedfrom an electronic catalog and the selected modules are assigned tothe required slots in the racks.
– The configuration of the distributed I/Os is done in the same wayas the configuration of the non-distributed I/Os; channel-granularI/O modules are also supported.
– CPU parameter assignment:
Properties such as restart characteristics and cycle-timemonitoring can be set menu-driven. multicomputing is supported. Theentered data are filed in system data blocks in the CPU.
– Module parameter assignment:
The user can specify all the adjustable parameters of the modulesin input screen forms. Adjustments via DIP switches becomeunnecessary. Parameterization of hardware modules occursautomatically during the CPU’s acceleration. Thus, a change of amodule can be made without another parameterization.
– Function module (FM) and communications processor (CP) parameterassignment:
This parameterization also occurs within the hardware configurationin the same way as the parameterization of the other modules. Forthis parameterization hardware-module-specific screen forms andrules are provided for each FM and CP (is included in the FM/CPfunctions package). The system prevents faulty inputs by offeringonly allowed entry options on the parameter assignment screenforms.
4. Communication configuration:
– Configuring and display of communication links
– Time-driven cyclic data transmission via MPI:
– Selection of communication partners
– Entering of data source and data destinationin a table.Generation of all system data blocks (SDBs) to be loadedand their complete transmission to all CPUs take placeautomatically
– Parameterization of the selected communicationblocks in the customary programming language (e.g., LAD).
– Event-driven data transmission
– Definition of the communication links.
– Selection of the communication function blocks (CFBs) from theintegrated block library.
– Parameterization of the selected communication blocks in thecustomary programming
language (e.g., LAD).
5. System diagnostics:
System diagnostics offer the user an overview of the status of theautomation system. The display can be in two different forms:
– Display of text messages, which can be output directly andquickly.
– Pixel-graphics display within the Hardware Config display,offering the following options:
– Display of general module information (e.g., order number,version, designation) and module status (e.g., faulty)
– Display of module faults (e.g., channel faults) of thecentral I/O and DP slaves
– Display of alarms from the diagnostics buffer
For CPUs, additional information is displayed:
– Causes of malfunction during user program execution.
– Display of cycle duration (longest, shortest and last cycle).
– Display of the reserved and free memory.
– Capabilities and usage of MPI communication.
– Display of the performance data (number of possibleinputs/outputs, flags, counters, timers and blocks)
Installer Size: 2889 MB
This video shows how to install correctly Simatic Manager Step 7 v5.6 Software
SIMATIC is a series of programmable logic controller and automation systems, developed by Siemens. Introduced in 1958, the series has gone through four major generations, the latest being the Simatic S7 generation. The series is intended for industrial automation and production.
The name Simatic is a registered trademark of Siemens. It is a portmanteau of “Siemens” and “Automatic”.
As with other programmable logic controllers, Simatic devices are intended to separate the control of a machine from the machine's direct operation, in a more lightweight and versatile manner than controls hard-wired for a specific machine. Early Simatic devices were transistor-based, intended to replace relays attached and customized to a specific machine. Microprocessors were introduced in 1973, allowing programs similar to those on general-purpose digital computers to be stored and used for machine control. Simatic devices have input and output modules to connect with controlled machines. The programs on the Simatic devices respond in real time to inputs from sensors on the controlled machines, and send output signals to actuators on the machines that directing their subsequent operation.
Depending on the device and its connection modules, signals may be a simple binary value ('high' or 'low') or more complex. For example, a binary input going from a thermometer on a machine to a Simatic device might have the following meanings:
Based on this input, and other factors, the program on the Simatic device might send a binary output signal to the same machine with the following meanings:
More complex inputs, outputs, and calculations were also supported as the Simatic line developed. For example, the Simatic 505 could handle floating point quantities and trigonometric functions.
Siemens has developed four product lines to date:
The S5 line was sold in 90U, 95U, 101U, 100U, 105, 110, 115,115U, 135U, and 155U chassis styles. The higher the number (except for the 101U), the more sophisticated and more expensive the system was. Within each chassis style, several CPUs were available, with varying speed, memory, and capabilities. Some systems provided redundant CPU operation for ultra-high-reliability control, as used in pharmaceutical manufacturing, for example.
Each chassis consisted of a power supply, and a backplane with slots for the addition of various option boards. Available options included serial and Ethernet communications, digital input and output cards, analog signal processing boards, counter cards, and other specialized interface and function modules.
The first entries in the S7 line were the S7-200, S7-300 and S7-400 series. These models were later succeeded by the S7-1200 and S7-1500 series.
Programs running on Simatic devices run in software environments created by Siemens. The environment varies by product line:
The S5 product line was usually programmed with a PC based software programming tool called STEP 5. STEP 5 was used for programming, testing, and commissioning, and for documentation of programs for S5 PLCs.
The original STEP 5 versions ran on the CP/M operating system. Later versions ran on MS-DOS, and then versions of Windows through Windows XP. The final version of STEP 5 was version 7.2 (upgradable to version 7.23 Hotfix 1 with patches).
In addition to STEP 5, Siemens offered a proprietary State logic programming package called Graph5. Graph5 is a sequential programming language intended for use on machines that normally run through a series of discrete steps. It simulates a State machine on the S5 platform.
Several third-party programming environments were released for the S5. Most closely emulated STEP 5, some adding macros and other minor enhancements, others functioning drastically differently from STEP 5. One allowed STEP 5 programs to be cross-compiled to and from the C programming language and BASIC.
STEP 5 allowed the creation of structured or unstructured programming, from simple AND/OR operations up to complex subroutines. A STEP 5 program may, therefore, contain thousands of statements.
To maintain maximum transparency, STEP 5 offers a number of structuring facilities:
STEP 5 programs can be represented in three different ways:
Absolute or symbolic designations can be used for operands with all three methods of representation.
In LAD and FBD complex functions and function block calls can be entered via function keys. They are displayed on the screen as graphical symbols.
There are several program editors, from either genuine Siemens, or from other suppliers. After Siemens discontinued support, other suppliers started to develop new STEP 5 version which can run on Windows XP, or Windows 7.
Five types of blocks are available:
Some S5 PLCs also have block types FX (Extended Function Blocks), and DX(Extended Data Blocks); these are not distinct block types, but rather are another set of available blocks due to the CPU having more memory and addressing space.
STEP 5 differentiates between three types of operations: